搜索资源列表
statcom_using_hysteresis_current_control_techniqu
- STATCOM WITH HYSTSEROS CONTROLELER FOR STUDYE
statcom_using_variable_dc_voltage_const_modulatio
- STATCOM WITH DC CONSTNT SOURCE WITH STUDY
upssdcvcvcvcdsdf1cmodel
- Statcom for DG system good one
power_statcom
- 这个例子显示了一个静止同步补偿器(STATCOM)用于中点电压调节的500千伏输电线路。-This example shows a Static Synchronous Compensator (STATCOM) used for midpoint voltage regulation on a 500-kV transmission line.
Optimal_location_of_STATCOM_in_multimachine
- a b s t r a c t A new metaheuristic method, the Cuckoo Search (CS) algorithm, based on the life of a bird family is proposed in this paper for optimal design of static synchronous compensator (STATCOM) in a multimachine environment. PV curves are i
LCL_sanjiao
- D-STATCOM仿真模型,三相四线制,同时补偿谐波无功不对称-D-STATCOM simulation model, three-phase four-wire system, while compensating harmonic reactive asymmetry
statcom_Apf
- STATCOM与有源滤波器的仿真,电流为滞环控制,含无功、谐波电流检测-STATCOM simulation with active filter, current hysteresis control, including reactive power, harmonic current detection
6-pulse-STATCOM
- 用于电网的无功功率控制仿真。这个值可以设置为零或常量值-Reactive power control simulation for the grid. This value can be set to zero or a constant value
IUPQC
- This paper presents an improved controller for the dual topology of the unified power quality conditioner (iUPQC) extending its applicability in power-quality compensation, as well as in microgrid applications. By using this controller, beyon
statcom_12pls
- A Simple 12-Pulse STATCOM. Reactive power control with PI controller. Fundamental frequency switching.
svc-dvr
- PSCAD simulation.Investigation D-STATCOM and DVR Operation for Voltage Control in Distribution Networks with a New Control Strategy
3
- STATCOM Control for Power System Voltage Control Applications
fddoc
- In this work an attempt is made to develop a STATCOM controller with MPC and the performance is analyzed by using MPC toolbox in MATLAB/Simulink
ggg
- the real power and reactive power waveform of STATCOM device with PI controller. The system settles down depending upon the gain values of PI controller. Due to the higher values of gain in PI controller, it causes peak overshoot in waveform at i
pso4
- Here the overshoot level of load voltage is 240 kV and response is settled at 0.10 sec, at the mean time the overshoot value of STATCOM current is 485 A and settled time is 0.14 sec respectively. When compared to PI controller response, the overs
dstatcom321
- d-statcom regulation de tension
Matlab44
- Analysis and Modelling of Static Synchronous Compensator (STATCOM): A comparison of Power Injection and Current Injection Models in Power Flow Study
Documento_completo-
- Analysis and Modelling of Static Synchronous Compensator (STATCOM): A comparison of Power Injection and Current Injection Models in Power Flow Study
sag_final
- sag model dvr and statcom-sag model dvr and statcom
wind_statcom
- 含风机和statcom补偿的小型输电系统,可以模拟风力波动、母线故障、风电投切造成的电能质量问题,并通过statcom补偿稳定母线电压并滤除谐波,效果较好,与大家分享。-The small power transmission system with fan and statcom compensation can simulate the power quality problems caused by wind power fluctuation, bus fault and wind po